73 research outputs found

    Mirror suspensions for the Glasgow Sagnac speed meter

    Get PDF
    A new era of gravitational wave astronomy has begun with the first direct detections of gravitational waves from the collision of binary black holes and a binary neutron star system. The scientific outcomes from these detections have been magnificent, however in order to increase the event rates for known sources, to be sensitive to new sources, to detect sources at greater distances, and to increase the signal to noise ratio for better extraction of source parameters, further research is required to increase the detectors sensitivity. The Advanced LIGO and Advanced Virgo detectors that enabled these first detections will ultimately be limited in their sensitivity by reaching the standard quantum limit (SQL). One novel technique to reduce the influence of quantum radiation pressure noise in a measurement of strain between two test masses is the speed meter topology. As a proof of concept experiment the Glasgow Sagnac Speed Meter experiment aims to show a reduction in quantum radiation pressure noise compared to an equivalent Michelson interferometer at audio-band frequencies. Two triangular cavities are the core of the experiment and consist of two 100g end test masses and one 1g input test masses per cavity, all suspended from multistage pendulums. In this combination the whole Sagnac Speed Meter experiment should be limited by quantum radiation pressure noise from about 100Hz to 1kHz and it is expected to achieve a reduction of quantum radiation pressure noise by a factor of 3-5 compared to an equivalent Michelson interferometer. This thesis presents the development, design, commissioning and testing of the three main types of suspensions in the Sagnac Speed Meter experiment. The longitudinal displacement noise requirement for both cavity suspension types is <1.5 x 10-18m/√Hz over the measurement band between 100Hz and about 1kHz. In order to isolate the mirrors from seismic ground motion in the Sagnac Speed Meter experiment, they are suspended from multistage pendulums, resulting ideally in a 1/f^2n response for n pendulum stages above the pendulums rigid body modes. Reduction of thermal noise in the suspension elements (suspension thermal noise) is achieved by the introduction of high quality-factor materials in the lowest pendulum stage, making it fully monolithic. The 100g end test mass suspension is based on an existing design, originally developed for the AEI 10m prototype, as a triple suspension with two stages of vertical blade springs and a fully monolithic lowest pendulum stage. The 1g input test mass suspension, designed as a quadruple pendulum with a fully monolithic lowest pendulum stage, utilises the same vertical blade springs and top mass as the 100g end test mass suspension. The quadruple pendulum design enables passive damping of test mass motion at the penultimate stage. As passive damping introduces force noise due to thermal noise, a switchable passive damping system was developed and tested to mitigate limitation by this force noise. The auxiliary suspension, a double pendulum, serves to suspend the mirrors in the experiment that guide the beam towards the Sagnac Speed Meter, in between the cavities, and towards the balanced homodyne detector. As these are not part of the cavities, the longitudinal displacement noise requirement can be relaxed to <8 x 10-15m/√Hz at 100Hz. The pendulum dynamics of the auxiliary and 100g end test mass suspension were measured in an optical lever set up and, in case of the auxiliary suspension, additionally with a vibrometer. With these measurements, the models were adjusted and could be used to estimate the longitudinal displacement noise due to coupling from seismic ground motion and thus verify the required performance of the suspensions. The research conducted in this thesis is an important step towards establishing the speed meter topology for consideration in future gravitational wave detectors. The developments in the scope of the monolithic assembly for the 100g end test masses will be applied to the AEI 10m prototype in order to enable sub-SQL measurements

    A new type of quantum speed meter interferometer: measuring speed to search for intermediate mass black holes

    Get PDF
    The recent discovery of gravitational waves (GW) by LIGO has impressively launched the novel field of gravitational astronomy and it allowed us to glimpse at exciting objects we could so far only speculate about. Further sensitivity improvements at the low frequency end of the detection band of future GW observatories rely on quantum non-demolition (QND) methods to suppress fundamental quantum fluctuations of the light fields used to readout the GW signal. Here we invent a novel concept of how to turn a conventional Michelson interferometer into a QND speed meter interferometer with coherently suppressed quantum back-action noise by using two orthogonal polarisations of light and an optical circulator to couple them. We carry out a detailed analysis of how imperfections and optical loss influence the achievable sensitivity and find that the configuration proposed here would significantly enhance the low frequency sensitivity and increase the observable event rate of binary black hole coalescences in the range of 102−103M⊙10^2-10^3 M_\odot by a factor of up to ∌300\sim300.Comment: 8 pages, 5 figures. Modified figures and text in v

    Sub-system mechanical design for an eLISA optical bench

    Get PDF
    We present the design and development status of the opto-mechanical sub-systems that will be used in an experimental demonstration of imaging systems for eLISA. An optical bench test bed design incorporates a ZerodurŸ baseplate with lenses, photodetectors, and other opto-mechanics that must be both adjustable - with an accuracy of a few micrometers - and stable over a 0 to 40°C temperature range. The alignment of a multi-lens imaging system and the characterisation of the system in multiple degrees of freedom is particularly challenging. We describe the mechanical design of the precision mechanisms, including thermally stable flexure-based optical mounts and complex multi-lens, multi-axis adjuster mechanisms, and update on the integration of the mechanisms on the optical bench

    Local-Oscillator Noise Coupling in Balanced Homodyne Readout for Advanced Gravitational Wave Detectors

    Get PDF
    The second generation of interferometric gravitational wave detectors are quickly approaching their design sensitivity. For the first time these detectors will become limited by quantum back-action noise. Several back-action evasion techniques have been proposed to further increase the detector sensitivity. Since most proposals rely on a flexible readout of the full amplitude- and phase-quadrature space of the output light field, balanced homodyne detection is generally expected to replace the currently used DC readout. Up to now, little investigation has been undertaken into how balanced homodyne detection can be successfully transferred from its ubiquitous application in table-top quantum optics experiments to large-scale interferometers with suspended optics. Here we derive implementation requirements with respect to local oscillator noise couplings and highlight potential issues with the example of the Glasgow Sagnac Speed Meter experiment, as well as for a future upgrade to the Advanced LIGO detectors.Comment: 7 pages, 5 figure

    Effects of static and dynamic higher-order optical modes in balanced homodyne readout for future gravitational waves detectors

    Get PDF
    With the recent detection of Gravitational waves (GW), marking the start of the new field of GW astronomy, the push for building more sensitive laser-interferometric gravitational wave detectors (GWD) has never been stronger. Balanced homodyne detection (BHD) allows for a quantum noise (QN) limited readout of arbitrary light field quadratures, and has therefore been suggested as a vital building block for upgrades to Advanced LIGO and third generation observatories. In terms of the practical implementation of BHD, we develop a full framework for analyzing the static optical high order modes (HOMs) occurring in the BHD paths related to the misalignment or mode matching at the input and output ports of the laser interferometer. We find the effects of HOMs on the quantum noise limited sensitivity is independent of the actual interferometer configuration, e.g. Michelson and Sagnac interferometers are effected in the same way. We show that misalignment of the output ports of the interferometer (output misalignment) only effects the high frequency part of the quantum noise limited sensitivity (detection noise). However, at low frequencies, HOMs reduce the interferometer response and the radiation pressure noise (back action noise) by the same amount and hence the quantum noise limited sensitivity is not negatively effected in that frequency range. We show that the misalignment of laser into the interferometer (input misalignment) produces the same effect as output misalignment and additionally decreases the power inside the interferometer. We also analyze dynamic HOM effects, such as beam jitter created by the suspended mirrors of the BHD. Our analyses can be directly applied to any BHD implementation in a future GWD. Moreover, we apply our analytical techniques to the example of the speed meter proof of concept experiment under construction in Glasgow. We find that for our experimental parameters, the performance of our seismic isolation system in the BHD paths is compatible with the design sensitivity of the experiment

    Demonstration of a switchable damping system to allow low-noise operation of high-Q low-mass suspension systems

    Get PDF
    Low mass suspension systems with high-Q pendulum stages are used to enable quantum radiation pressure noise limited experiments. Utilising multiple pendulum stages with vertical blade springs and materials with high quality factors provides attenuation of seismic and thermal noise, however damping of these high-Q pendulum systems in multiple degrees of freedom is essential for practical implementation. Viscous damping such as eddy-current damping can be employed but introduces displacement noise from force noise due to thermal fluctuations in the damping system. In this paper we demonstrate a passive damping system with adjustable damping strength as a solution for this problem that can be used for low mass suspension systems without adding additional displacement noise in science mode. We show a reduction of the damping factor by a factor of 8 on a test suspension and provide a general optimisation for this system.Comment: 5 pages, 5 figure

    Molecular MRI in the Earth's Magnetic Field Using Continuous Hyperpolarization of a Biomolecule in Water

    Get PDF
    In this work, we illustrate a method to continuously hyperpolarize a biomolecule, nicotinamide, in water using parahydrogen and signal amplification by reversible exchange (SABRE). Building on the preparation procedure described recently by Truong et al. [ J. Phys. Chem. B, 2014, 118, 13882-13889 ], aqueous solutions of nicotinamide and an Ir-IMes catalyst were prepared for low-field NMR and MRI. The 1H-polarization was continuously renewed and monitored by NMR experiments at 5.9 mT for more than 1000 s. The polarization achieved corresponds to that induced by a 46 T magnet (P = 1.6 × 10-4) or an enhancement of 104. The polarization persisted, although reduced, if cell culture medium (DPBS with Ca2+ and Mg2+) or human cells (HL-60) were added, but was no longer observable after the addition of human blood. Using a portable MRI unit, fast 1H-MRI was enabled by cycling the magnetic field between 5 mT and the Earth's field for hyperpolarization and imaging, respectively. A model describing the underlying spin physics was developed that revealed a polarization pattern depending on both contact time and magnetic field. Furthermore, the model predicts an opposite phase of the dihydrogen and substrate signal after one exchange, which is likely to result in the cancelation of some signal at low field

    Efficacy and safety of N-acetyl-l-leucine in Niemann–Pick disease type C

    Get PDF
    Objective: To investigate the safety and efficacy of N-acetyl-L-leucine (NALL) on symptoms, functioning, and quality of life in pediatric (≄ 6 years) and adult Niemann-Pick disease type C (NPC) patients. Methods: In this multi-national, open-label, rater-blinded Phase II study, patients were assessed during a baseline period, a 6-week treatment period (orally administered NALL 4 g/day in patients ≄ 13 years, weight-tiered doses for patients 6-12 years), and a 6-week post-treatment washout period. The primary Clinical Impression of Change in Severity (CI-CS) endpoint (based on a 7-point Likert scale) was assessed by blinded, centralized raters who compared randomized video pairs of each patient performing a pre-defined primary anchor test (8-Meter Walk Test or 9-Hole Peg Test) during each study periods. Secondary outcomes included cerebellar functional rating scales, clinical global impression, and quality of life assessments. Results: 33 subjects aged 7-64 years with a confirmed diagnosis of NPC were enrolled. 32 patients were included in the primary modified intention-to-treat analysis. NALL met the CI-CS primary endpoint (mean difference 0.86, SD = 2.52, 90% CI 0.25, 1.75, p = 0.029), as well as secondary endpoints. No treatment-related serious adverse events occurred. Conclusions: NALL demonstrated a statistically significant and clinical meaningfully improvement in symptoms, functioning, and quality of life in 6 weeks, the clinical effect of which was lost after the 6-week washout period. NALL was safe and well-tolerated, informing a favorable benefit-risk profile for the treatment of NPC. CLINICALTRIALS. Gov identifier: NCT03759639

    A Cryogenic Silicon Interferometer for Gravitational-wave Detection

    Get PDF
    The detection of gravitational waves from compact binary mergers by LIGO has opened the era of gravitational wave astronomy, revealing a previously hidden side of the cosmos. To maximize the reach of the existing LIGO observatory facilities, we have designed a new instrument that will have 5 times the range of Advanced LIGO, or greater than 100 times the event rate. Observations with this new instrument will make possible dramatic steps toward understanding the physics of the nearby universe, as well as observing the universe out to cosmological distances by the detection of binary black hole coalescences. This article presents the instrument design and a quantitative analysis of the anticipated noise floor

    A Cryogenic Silicon Interferometer for Gravitational-wave Detection

    Get PDF
    The detection of gravitational waves from compact binary mergers by LIGO has opened the era of gravitational wave astronomy, revealing a previously hidden side of the cosmos. To maximize the reach of the existing LIGO observatory facilities, we have designed a new instrument able to detect gravitational waves at distances 5 times further away than possible with Advanced LIGO, or at greater than 100 times the event rate. Observations with this new instrument will make possible dramatic steps toward understanding the physics of the nearby Universe, as well as observing the Universe out to cosmological distances by the detection of binary black hole coalescences. This article presents the instrument design and a quantitative analysis of the anticipated noise floor
    • 

    corecore